{"affected":[{"defaultStatus":"affected","product":"Nexsmart Guardian 2 (Alarm system)","source":"CNA: ENISA","vendor":"Onyx Cookware ApS","versions":[{"status":"affected","version":"0","versionType":"semver"}]}],"cveId":"CVE-2026-82949","cwes":["CWE-319"],"description":"The static codes used for information transmission\nthroughout the 433.92 MHz system of the Guardian 2 system allow an attacker in\nproximity to monitor the movements of users inside the premises where the\nsensors are set up. This is further aided by the fact that codes transmitted\nreveal sensor type, although sensor location cannot be inferred from this\ntraffic alone.","epss":{"date":"2026-11-23","percentile":0.03483,"score":0.00142},"exploits":[],"kev":null,"metrics":[{"score":7.1,"severity":"high","source":"CNA: ENISA","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},{"score":7.1,"severity":"high","source":"NVD: a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0"}],"modifiedAt":1795542643383,"publishedAt":1795084333090,"references":[{"source":"CNA: ENISA","tags":[],"url":"https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c"},{"source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","tags":[],"url":"https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c"}],"remediation":[{"kind":"fix","source":"CNA: ENISA","text":"Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart \nthrough its official support channels and ask about any current \nremediation guidance."}],"revision":"dbe7a705b225ceec1dd6a8ca2b51c282ffd89508c16962df722eb0cf9ffe8c43","sources":[{"modifiedAt":1795101055174,"name":"CNA: ENISA","retrievedAt":1795105659251,"url":"https://www.cve.org/CVERecord?id=CVE-2026-82949"},{"modifiedAt":1795542643383,"name":"NVD","retrievedAt":1795544228379,"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-82949"},{"modifiedAt":null,"name":"FIRST EPSS","retrievedAt":1795502946152,"url":"https://api.first.org/data/v1/epss?cve=CVE-2026-82949"}],"ssvc":{"assessedAt":1795101044258,"automatable":"no","exploitation":"none","source":"ADP: CISA-ADP","technicalImpact":"partial"},"status":"published","title":"Occupancy monitoring via unencrypted RF communication","updatedAt":1795544228379}