{"affected":[{"defaultStatus":"unaffected","product":"Infantia","source":"CNA: ENISA","vendor":"CompuGroup Medical","versions":[{"lessThanOrEqual":"6.09.1","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"Profim","source":"CNA: ENISA","vendor":"CompuGroup Medical","versions":[{"lessThanOrEqual":"6.09.1","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"Venere","source":"CNA: ENISA","vendor":"CompuGroup Medical","versions":[{"lessThanOrEqual":"8.33.2","status":"affected","version":"0","versionType":"semver"}]}],"cveId":"CVE-2026-118795","cwes":["CWE-602"],"description":"Administrative roles and module permissions are stored in mutable local database fields, allowing privilege escalation for attackers with database write access.","epss":null,"exploits":[],"kev":null,"metrics":[{"score":5.9,"severity":"medium","source":"CNA: ENISA","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U","version":"4.0"}],"modifiedAt":1794225893081,"publishedAt":1794225893081,"references":[{"source":"CNA: ENISA","tags":[],"url":"https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"},{"source":"CNA: ENISA","tags":[],"url":"https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"}],"remediation":[],"revision":"9d16104b8f0085a55311f801e11a32d7d9855bdc03d83731db56b0f70bb093fb","sources":[{"modifiedAt":1794225893081,"name":"CNA: ENISA","retrievedAt":1794229714198,"url":"https://www.cve.org/CVERecord?id=CVE-2026-118795"}],"ssvc":null,"status":"published","title":"AIS stores authorization state in locally modifiable databases","updatedAt":1794229714198}